Safe speed monitors with SIL3/PLe and SIL2/PLd certification
In industrial applications, there is often a high risk for people
and machines. In these cases it is necessary and required by law
to meet certain safety criteria in order to reduce these risks.
This is exactly where the DS series speed monitors come into play.
These are used to monitor under-frequencies, over-frequencies,
the direction of rotation and the standstill of machines. With
their SIL3 / PLe and SIL2 / PLd certifications according to the
standards DIN 61508 and ISO 13849, the safety relays guarantee
maximum safety and reliability.
DS260: Safe speed monitor for incremental encoders / sensors
Safe speed monitor for incremental encoders /
sensors for monitoring ramps, underspeed,
overspeed, standstill and direction of rotation,
with line break monitoring of the sensor signals.
Up to SIL3/PLe with an equally certified sensor.
-Safety functions equivalent to EN 61800-5-2
(SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
-Incremental encoder input in format A, /A, B, /B, Z, /Z
[HTL differential, RS422]
-8 control inputs [HTL / PNP]
-Input frequency up to 500 kHz
-2 synchronizing relay outputs 5... 250 VAC / VDC (NO)
-4 x 2 control outputs with push-pull characteristics, short-circuit proof, [HTL],
complementary or equivalent redundant or single use
-Safe 14-bit analog output for 4 ... 20 mA (scalable)
DS250: Safe speed monitor for incremental encoders / sensors
Design like DS260, but up to SIL3/PLe with two independent, non-certified sensors and with 2 incremental encoder inputs.
BG200: Attachable display and adjustment module
The BG200 display device is used for the motrona
safety devices of the DS series. It has a large
number of visualization functions and, thanks to
its intuitive operation, can be used quickly,
easily and flexibly.
The BG200 offers the following features on the safety:
- Two-channel frequency display
- Individually scalable for e.g. B. speeds, production rates, etc.
- Representation of operating mode and error mode
DS240: Safe speed monitor with SinCos encoder input, signal distributor
The safe speed monitors for SinCos sensors are
ideally suited for monitoring the direction of
rotation, standstill, underspeed and overspeed.
-Safety functions equivalent to EN 61800-5-2
(SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
-1 encoder input in the format SIN+, SIN-, COS+, COS- [1 Vss]
-2 control inputs [HTL / PNP]
-Input frequency up to 500 kHz
-Forced redundant output relay (NO)
-4 control outputs with push-pull characteristics, short-circuit proof, [HTL],
each inverse and redundant
-Safe 14-bit analog output for 4 ... 20 mA (scalable)
DS246: Safe speed monitor with SinCos encoder input
Design like DS240, but without signal splitter.
DS230: Safe speed monitor with multifunction inputs for HTL, RS422, SinCos sensors
and signal distributors
Same design as DS240, but with a different input configuration.
-Safety functions equivalent to EN 61800-5-2
(SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
-2 encoder inputs in the format SIN+, SIN-, COS+, COS- [1 Vss]
-2 pulse inputs in format A, /A, B, /B [RS422]
-2 pulse or control inputs in format A, B, 90° [HTL / PNP]
(for encoders, proximity switches or control commands)
-Input frequency up to 500 kHz
-Forced redundant output relay (NO)
-4 control outputs with push-pull characteristics, short-circuit proof, [HTL],
each inverse and redundant
-Safe 14-bit analog output for 4 ... 20 mA (scalable)
DS236: Safe speed monitor with multifunction inputs for HTL, RS422 and
SinCos sensors without signal distributor
Design like DS230, but without signal splitter.